Glucose-responsive probiotics… · 2026
VeriQuant™ · Proximity Ligation Assay
Less sample.
More answers.
Sensitivity down to 10 fg/mL, quantified from just 1–5 µL of sample.
VeriQuant™ converts protein recognition into exponentially amplifiable nucleic acid signals using a proximity ligation assay (PLA), so low-abundance inflammatory factors, trace serum and precious samples such as cerebrospinal fluid can be accurately quantified.
A wider dynamic range.
A lower detection limit.
One-pot reaction.
No prolonged incubation, no repeated concentration. One test, spanning 6 orders of magnitude in concentration. The entire experiment was conducted in the same well without any liquid transfer during the process.
01 Sensitivity/PLA signal amplification
Low-abundance targets,
still clearly visible.
The high-affinity pairing monoclonal antibody is paired with a self-developed Lytix coupling system, which converts protein signals into nucleic acid signals and exponentially amplifies them to accurately capture the trace fluctuations of IL-6, TNF-α, and IL-1β.
02 Micro-sample/1–5 μL loading
Precious samples,
one tube, many answers.
Bronchoalveolar lavage fluid, mouse cerebrospinal fluid, trace serum — no concentration or pre-treatment. One sample can be measured across more markers without repeat sampling.
MULTIPLEX Experimental testing service
Explore the service ↗03 Stability / wash-free workflow
Leave error
to process control.
A streamlined, no-wash protocol limits manual variability. Intra-assay CV <5%, inter-assay CV <8%, recovery around 95% — five quality gates protect every batch.
04 Automated/Universal qPCR Equipment
Two hours end to end,
no dedicated instrument.
Around 30 minutes of hands-on time with standard qPCR consumables; the automated workflow handles plate sealing, bringing high-throughput testing into everyday use.
Reed Biotech · Products
Your experiment, your pace.
Every line in one place.
From classic ELISA to ultra-sensitive PLA immunoassays, covering antibodies, recombinant proteins and biochemical reagents, every protein quantification question has a corresponding answer.
VeriQuant™ Immunoassay
Femtogram-level signal,
1–5 µL sample.
Proximity ligation plus qPCR amplification, a no-wash plate, results in about two hours on any standard qPCR instrument.
ELISA Kits
FS & MF series kit
Fast Step and Micro Fast series, with PolyHRP amplification balancing sensitivity and workflow speed; human, mouse, rat and other species.
Reagents
Antibodies · Proteins · Biochemical agents
Primary and secondary antibodies, cytokines, oxidative-stress and metabolism panels, plus supporting reagents and online calculation tools — the full experimental chain in one place.
Plate layout · duplicate wells
Flux estimation
According to the double double well calculation of each sample, the number of samples that can be accommodated on a single board can be estimated by switching the plate type, and the allocation of precious samples can be planned in advance.
96 wells ÷ 2 duplicates = 48 samples / plate
The estimated value is only for the reference of the experimental design, and the specifics are subject to the product specification.
Method comparison
Method comparison,
without compromise.
Sensitivity, sample volume, workflow and instrumentation, side by side. VeriQuant figures are aggregated from our own catalogue; the two conventional formats are shown at their typical method-class performance.
| Capability | Conventional ELISATypical · method class | Three-step BAS sandwichTypical · method class | VeriQuant™Measured · 40 catalogue kits |
|---|---|---|---|
| Sensitivity (LoD) | 0.1–10 ng/mL | 10–500 pg/mL | 0.005–1.42 pg/mL5–1,420 fg/mL · median 0.082 pg/mL |
| Detection range | ≈2 orders of magnitude | 3–4 orders of magnitude | 4.19 log on every kitsame span across all 40 kits |
| Sample volume | 50–100 µL per well | ≈50 µL per well | 1–5 µL per well |
| Wash steps | 3–5 wash cycles | 4–6 wash cycles | None — homogeneousno wash, no plate-to-plate transfer |
| Hands-on time | 60–90 min | 60–90 min | 20 min |
| Time to result | 3–5 h | 4–5 h | 2 h |
| Instrument | Microplate reader (absorbance) | Microplate reader (absorbance) | Standard qPCR instrumentFAM™ channel · 96-well block |
| Sample types | Serum, plasma (diluted) | Serum, plasma (diluted) | Six matrices, including tissue and cell lysateserum · plasma · tissue homogenate · cell lysate · culture supernatant · other fluids |
| Lot-level data | Standard curve | Standard curve + recovery | Full panel, every lotstandard curve · spike recovery · dilution linearity · within- and between-run precision |
Conventional ELISA and three-step BAS values are typical ranges for the method class, not claims about any specific supplier; individual assays differ. VeriQuant values are aggregated from the 40 VeriQuant kits catalogued on this site (November 2026): sensitivity is the kit-level limit of detection, range span is log10(highest / lowest standard). The kit insert remains the authoritative specification.
Evidence in practice · Technical resources
Real samples.
High-impact publications.
Microbiome · 2026
ALLERGY · 2026
Find your kit
Your question.
Your kit.
Filter by indicator, species and sample type,
Or chat directly with our technical team about custom solutions.
Need to count concentrations or calibrations?Online tools ↗