VeriQuant™ · Proximity Ligation Assay

Less sample.
More answers.

Sensitivity down to 10 fg/mL, quantified from just 1–5 µL of sample.

VeriQuant™ converts protein recognition into exponentially amplifiable nucleic acid signals using a proximity ligation assay (PLA), so low-abundance inflammatory factors, trace serum and precious samples such as cerebrospinal fluid can be accurately quantified.

A wider dynamic range.
A lower detection limit.
One-pot reaction.

No prolonged incubation, no repeated concentration. One test, spanning 6 orders of magnitude in concentration. The entire experiment was conducted in the same well without any liquid transfer during the process.

01 Sensitivity/PLA signal amplification

Low-abundance targets,
still clearly visible.

The high-affinity pairing monoclonal antibody is paired with a self-developed Lytix coupling system, which converts protein signals into nucleic acid signals and exponentially amplifies them to accurately capture the trace fluctuations of IL-6, TNF-α, and IL-1β.

02 Micro-sample/1–5 μL loading

Precious samples,
one tube, many answers.

Bronchoalveolar lavage fluid, mouse cerebrospinal fluid, trace serum — no concentration or pre-treatment. One sample can be measured across more markers without repeat sampling.

MULTIPLEX Experimental testing service

Explore the service ↗

03 Stability / wash-free workflow

Leave error
to process control.

A streamlined, no-wash protocol limits manual variability. Intra-assay CV <5%, inter-assay CV <8%, recovery around 95% — five quality gates protect every batch.

04 Automated/Universal qPCR Equipment

Two hours end to end,
no dedicated instrument.

Around 30 minutes of hands-on time with standard qPCR consumables; the automated workflow handles plate sealing, bringing high-throughput testing into everyday use.

Scroll to explore
Back to top ↑

Reed Biotech · Products

Your experiment, your pace.
Every line in one place.

From classic ELISA to ultra-sensitive PLA immunoassays, covering antibodies, recombinant proteins and biochemical reagents, every protein quantification question has a corresponding answer.

VeriQuant™ Immunoassay

Femtogram-level signal,
1–5 µL sample.

Proximity ligation plus qPCR amplification, a no-wash plate, results in about two hours on any standard qPCR instrument.

ELISA Kits

FS & MF series kit

Fast Step and Micro Fast series, with PolyHRP amplification balancing sensitivity and workflow speed; human, mouse, rat and other species.

Reagents

Antibodies · Proteins · Biochemical agents

Primary and secondary antibodies, cytokines, oxidative-stress and metabolism panels, plus supporting reagents and online calculation tools — the full experimental chain in one place.

Plate layout · duplicate wells

Flux estimation

According to the double double well calculation of each sample, the number of samples that can be accommodated on a single board can be estimated by switching the plate type, and the allocation of precious samples can be planned in advance.

96 wells ÷ 2 duplicates = 48 samples / plate

The estimated value is only for the reference of the experimental design, and the specifics are subject to the product specification.

Method comparison

Method comparison,
without compromise.

Sensitivity, sample volume, workflow and instrumentation, side by side. VeriQuant figures are aggregated from our own catalogue; the two conventional formats are shown at their typical method-class performance.

CapabilityConventional ELISATypical · method classThree-step BAS sandwichTypical · method classVeriQuant™Measured · 40 catalogue kits
Sensitivity (LoD)0.1–10 ng/mL10–500 pg/mL0.005–1.42 pg/mL5–1,420 fg/mL · median 0.082 pg/mL
Detection range≈2 orders of magnitude3–4 orders of magnitude4.19 log on every kitsame span across all 40 kits
Sample volume50–100 µL per well≈50 µL per well1–5 µL per well
Wash steps3–5 wash cycles4–6 wash cyclesNone — homogeneousno wash, no plate-to-plate transfer
Hands-on time60–90 min60–90 min20 min
Time to result3–5 h4–5 h2 h
InstrumentMicroplate reader (absorbance)Microplate reader (absorbance)Standard qPCR instrumentFAM™ channel · 96-well block
Sample typesSerum, plasma (diluted)Serum, plasma (diluted)Six matrices, including tissue and cell lysateserum · plasma · tissue homogenate · cell lysate · culture supernatant · other fluids
Lot-level dataStandard curveStandard curve + recoveryFull panel, every lotstandard curve · spike recovery · dilution linearity · within- and between-run precision

Conventional ELISA and three-step BAS values are typical ranges for the method class, not claims about any specific supplier; individual assays differ. VeriQuant values are aggregated from the 40 VeriQuant kits catalogued on this site (November 2026): sensitivity is the kit-level limit of detection, range span is log10(highest / lowest standard). The kit insert remains the authoritative specification.

Evidence in practice · Technical resources

Real samples.
High-impact publications.

IF 56.702 · NATURE
Engineered Probiotics for Closed Loop Glucose Reduction

Glucose-responsive probiotics… · 2026

IF 18.5 · Microbiome
Dysbiosis of intestinal flora and spermatogenesis

Microbiome · 2026

IF 11.695 · ALLERGY
IgG/IgE mediated recurrent severe allergies

ALLERGY · 2026

View all technical resources →

Find your kit

Your question.
Your kit.

Filter by indicator, species and sample type,
Or chat directly with our technical team about custom solutions.

Need to count concentrations or calibrations?Online tools ↗