REEDBIOTECH PRODUCT DATA / ORIGINAL RECORDS

—

Products Data

The following parameters and validation records are from the original product data sheet.

01 / OVERVIEW

Overview

The complete Chinese introduction of the source table is rendered as is, including the applicable sample type; it is not compressed for summary or replaced with marketing copy.

Loading product summary…
02 / SPECIFICATIONS

Full specification

Field by field lists product identity, performance parameters and classification attribution. The blank field shows ”—” and does not fill in the guess value.

03 / STANDARD CURVE

Four-parameter logistic (4PL) standard curve

Measured OD points are fitted with y = d + (a − d) / (1 + (x/c)^b). Both axes use a log10 scale, with the start and end values chosen automatically from the measured data range; tick labels still give the original concentration and OD values, and a small offset keeps zero blanks visible. The fit itself stays in linear OD. A sandwich ELISA gives an increasing curve (d > a); a competitive ELISA gives a decreasing curve (a > d). The fitted line, the original measured dots and the fitted OD for every point are shown together.

04 / TECHNICAL DATA

Product performance

Due to differences in experimental conditions (operator, pipetting technique, plate washing and incubation conditions), the OD values of the standard curve may vary. The data and curves below are for reference only; users should establish their own standard curve under their own experimental conditions.

01

Precision

Within-run precision: low-, medium- and high-concentration samples were each measured 20 times on one plate. Between-run precision: low-, medium- and high-concentration samples were each measured 20 times on three plates.

02

Spike recovery

A known concentration of the target protein was added to five different samples of each matrix for the spike-recovery experiment; the observed recovery range and the mean recovery were calculated from those results.

03

Linearity

Five spiked samples per matrix were diluted 2-fold, 4-fold, 8-fold and 16-fold; the recovery range and the mean recovery were calculated for each dilution.

SOURCE: uploaded ELISA catalogue columns RRS–BYXSB3 (48 measured fields). Values are reproduced verbatim; ranges are observed minimum–maximum values, not declared acceptance limits. A dash means the source table has no value for that cell.

Aggregated validation records from the source database

FOUR MATRICES · FOUR MATRIX KEY INDICATORS

LINEARITY · FOUR MATRICES × RECOVERY PERCENTAGE OF EACH DILUTION

05 / CITATIONS

Publications citing this product

Reverse check according to the article number text in the original paper. Preprint is labeled separately, and non-public entries are not displayed according to the Editorial policy.

07 / ORDER & DOCS

Ordering & technical documents

SKUs with public prices directly display the source table price text; guided inquiries without prices, no placeholder numbers.

08 / DATA PROVENANCE

Data sources & conventions

Traceability

Each field goes back to the original record