PRODUCTS

Catalog Number:FS2855H
FS-Human ENA-78/CXCL5(Epithelial Neutrophil Activating Peptide 78) ELISA Kit
Copy Product Information

Size:

96 T

48 T

Price:

Inquiry

Inquiry

Delivery: Order now, ship in 3 days

Product Details
Product Name FS-Human ENA-78/CXCL5(Epithelial Neutrophil Activating Peptide 78) ELISA Kit Species Human
Uniprot ID P42830 Alternative Names chemokine (C-C motif) ligand 5, C-X-C motif chemokine 5, CXCL5, CXCL5/ENA-78, ENA78, ENA-78, ENA-78(1-78), Epithelial-derived neutrophil-activating protein 78, Neutrophil-activating peptide ENA-78, neutrophil-activating protein 78, SCYB5ENA78
Detection method Sandwich Sensitivity 1.78 pg/mL
Standard 500pg/mL Detection Range 7.81-500pg/mL
Sample type Serum, Plasma, Tissue homogenates, Cell lysates, Cell culture supernates and Other biological fluids;Sample Volume=50μL
Reaction time 1.5H Research Area Cancer, Immunology;
Test principle This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human ENA-78/CXCL5. Samples (or Standards) and Horseradish Peroxidase (HRP) linked antibody specific for Human ENA-78/CXCL5 are added to the micro ELISA plate wells. Human ENA-78/CXCL5 in samples (or standards) combines with the coated antibody and HRP linked detection antibody special to Human ENA-78/CXCL5. Excess conjugate and unbound sample or standard are washed from the plate. The substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450±2 nm. The OD value is proportional to the concentration of Human ENA-78/CXCL5. The concentration of Human ENA-78/CXCL5 in the samples is then determined by comparing the OD of the samples to the standard curve.
Technical Data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

(pg/mL) OD Corrected
500.00 2.563 2.506
250.00 1.732 1.675
125.00 0.983 0.926
62.50 0.477 0.420
31.25 0.281 0.224
15.63 0.135 0.078
7.82 0.105 0.048
0.00 0.057
Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.

Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean(pg/mL) 12.83 95.80 184.45 12.32 95.80 189.98
Standard deviation 1.01 3.59 14.00 0.64 3.75 8.17
C V (%) 7.87 3.75 7.59 5.19 3.91 4.30
Rate of recovery

The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range(%) Average Recovery(%)
Serum (n=8) 90-105 97
EDTA plasma (n=8) 80-95 87
Cell culture media (n=8) 83-95 89
Linear

Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 80-91 86-97 92-105
Average (%) 81 97 93
1:4 Range (%) 89-103 86-97 87-98
Average (%) 90 88 95
1:8 Range (%) 82-95 90-98 85-92
Average (%) 92 97 91
1:16 Range (%) 86-99 80-93 80-96
Average (%) 94 87 95
Assay Procedures