Catalog Number:RE10067
ADP(Adenosine Diphosphate) ELISA Kit
Copy Product Information

Size:

96 T

48 T

Price:

Inquiry

Inquiry

Delivery: Order now, ship in 3 days

Product Details
Product Name ADP(Adenosine Diphosphate) ELISA Kit Species Universal
Uniprot ID N/A Alternative Names Adenosine Diphosphate
Detection method Competitive Sensitivity 9.38 ng/mL
Standard 1000ng/mL Detection Range 15.63-1000ng/mL
Sample type Serum, Plasma, Tissue homogenates, Cell lysates, Cell culture supernates and Other biological fluids, Sample volume: 50μL
Reaction time 1.5H Research Area Metabolic pathway; Signal Transduction; Cancer, Nutrition metabolism;Hormone metabolism; Signal transduction;Metabolic pathway; Enzyme & Kinase; Signal transduction;Metabolic pathway; Nutrition metabolism;Hormone metabolism;Cardiovascular,Signaling transduction,Neuroscience,Cancer,Metabolism; Enzyme & Kinase;Infection immunity;Endocrinology;Hormone metabolism; Metabolic pathway; Signal Transduction; Cancer
Test principle This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with ADP. During the reaction, ADP in the sample or standard competes with a fixed amount of ADP on the solid phase supporter for sites on the Biotinylated Detection Ab specific to ADP. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of ADP in tested samples can be calculated by comparing the OD of the samples to the standard curve.
Technical Data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

(ng/mL) OD
1000.00 0.279
500.00 0.379
250.00 0.573
125.00 0.834
62.50 1.129
31.25 1.524
15.63 1.838
0.00 2.502
Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.

Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean(ng/mL) 49.260 158.020 384.840 50.320 167.480 388.990
Standard deviation 2.460 7.900 19.240 2.520 8.370 19.450
C V (%) 4.28 5.75 3.59 4.43 5.81 3.72
Rate of recovery

The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range(%) Average Recovery(%)
Serum (n=8) 85-99 92
EDTA plasma (n=8) 80-92 85
Cell culture media (n=8) 80-90 84
Linear

Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 88-102 81-94 86-97
Average (%) 96 84 92
1:4 Range (%) 96-107 81-94 80-94
Average (%) 106 90 89
1:8 Range (%) 89-103 80-90 90-99
Average (%) 93 84 95
1:16 Range (%) 80-95 83-95 87-103
Average (%) 80 85 100
Assay Procedures