PRODUCTS

Catalog Number:FSA2731M
FS-Mouse MCP-1(Monocyte Chemotactic Protein 1) ELISA Kit
Copy Product Information

Size:

96 T

48 T

Price:

Inquiry

Inquiry

Delivery: Order now, ship in 3 days

Product Details
Product Name FS-Mouse MCP-1(Monocyte Chemotactic Protein 1) ELISA Kit Species Mouse
Uniprot ID P10148 Alternative Names CCL2; GDCF2; HC11; HSMCR30; MCAF; MCP1; SCYA2; SMC-CF; Chemokine C-C-Motif Ligand 2; Monocyte Chemotactic And Activating Factor; Monocyte Secretory Protein JE
Detection method Sandwich Sensitivity 9.36 pg/mL
Standard 1000pg/mL Detection Range 15.63-1000pg/mL
Sample type Serum, Plasma and Tissue homogenate and Other biological samples;Sample volume:50μL
Reaction time 1.5H Research Area Cardiovascular, Signaling transduction, Cancer, Metabolism, Stem Cells
Test principle This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to TGF-β1. Samples (or Standards) are added to the micro ELISA plate wells and combined with the specific antibody and biotinylated detection antibody specific for TGF-β1. Then Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain TGF-β1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The OD value is proportional to the concentration of TGF-β1. You can calculate the concentration of TGF-β1 in the samples by comparing the OD of the samples to the standard curve.
Technical Data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

(pg/mL) OD Corrected
1000.00 2.566 2.525
500.00 1.849 1.808
250.00 1.071 1.030
125.00 0.696 0.655
62.50 0.315 0.274
31.25 0.153 0.112
15.63 0.119 0.078
0.00 0.041
Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.

Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean(pg/mL) 41.828 170.143 597.500 44.069 130.000 363.500
Standard deviation 3.208 11.195 43.259 3.147 7.566 26.972
C V (%) 7.67 6.58 7.24 7.14 5.82 7.42
Rate of recovery

The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range(%) Average Recovery(%)
Serum (n=8) 94-102 98
EDTA plasma (n=8) 96-102 99
Cell culture media (n=8) 86-95 90
Linear

Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 95-103 93-100 95-104
Average (%) 98 96 100
1:4 Range (%) 97-104 91-100 90-98
Average (%) 101 96 95
1:8 Range (%) 97-104 97-106 97-106
Average (%) 101 101 102
1:16 Range (%) 90-99 92-99 97-106
Average (%) 94 95 102